Internal injury in the body, bone, joint damage titanium plate caused by tumors, the use of titanium and titanium alloy-made artificial joints, bone plates and screws, are now widely used in clinical practice. Also for hip joint (including the femoral head), knee, elbow, metacarpophalangeal joints, interphalangeal joint, mandible, artificial vertebral (spinal orthotics), cardiac titanium alloy bar pacing instrument shell, artificial heart (heart valves). dental Implants, orthodontic nickel titanium and titanium mesh in skull is shaping other aspects.
Medical titanium rod for ingot production and processing of materials should be used to vacuum consumable arc melting furnace smelting or EB plus vacuum consumable arc melting, melting of not less than twice the number of
2015年7月13日星期一
2015年7月9日星期四
The company mainly produces titanium pipe price civilian titanium and titanium alloy materials. Including: titanium tube, cold-rolled tube, condenser tube, capillary tube, titanium pipe, titanium pipe, titanium coil, titanium coil, titanium tube, titanium plate; cold-rolled plate, hot-rolled sheet steel, titanium titanium spring wire steel composite materials, rods, titanium rings, titanium flange, titanium elbow, titanium bolts, titanium screws, titanium wire, titanium wire, titanium rivets and various titanium machining parts, complex parts. Run-nickel pipes, nickel plate, nickel rods, nickel wire, zirconium and other non-ferrous materials products.
2015年7月6日星期一
Titanium is a very reactive metal, its potential medical titanium alloy is very low equilibrium thermodynamic corrosion tendency in the medium is large. But in fact titanium is very stable in many media, such as titanium oxide, neutral and weakly reducing medium such as corrosion resistant. This is because the titanium and oxygen has a great affinity, in the air or an oxygen-containing medium, the titanium surface layer of dense, strong adhesion, large inert oxide film, a titanium substrate protection against corrosion. material titanium Even due to mechanical wear and tear will heal or regenerate quickly. This shows that titanium metal has a strong tendency to passivation. Oxide film medium temperature below 315 ℃ titanium remain this feature
.
.
2015年6月29日星期一
Titanium operating temperature up to 500 ℃
Medical titanium plate temperature of several hundred degrees higher than aluminum, at moderate temperatures can still maintain the desired strength, long-term work of these two types of titanium alloy in the range of 150 ℃ ~ 500 ℃ still very high strength at a temperature of 450 ~ 500 ℃, and aluminum alloys decreased significantly at 150 ℃ than strength. Surgical implant titanium Titanium operating temperature up to 500 ℃, aluminum is below 200 ℃.
Medical titanium alloy working in a humid atmosphere and seawater, the corrosion resistance is far superior to stainless steel; for pitting, etching, stress corrosion resistance is particularly strong; to have excellent corrosion resistance bases, chloride, chlorine organic materials, nitric acid, sulfuric acid and the like. However, the corrosion resistance of titanium with a reduction of oxygen and chromium salts medium is poor.
Titanium alloys at low and ultra-low temperature, retain their mechanical properties. Low temperature performance, low interstitial elements of titanium, such as TA7, at -253 ℃ can maintain a certain degree of plasticity. Thus, titanium is also an important low temperature structural materials.
Medical titanium alloy working in a humid atmosphere and seawater, the corrosion resistance is far superior to stainless steel; for pitting, etching, stress corrosion resistance is particularly strong; to have excellent corrosion resistance bases, chloride, chlorine organic materials, nitric acid, sulfuric acid and the like. However, the corrosion resistance of titanium with a reduction of oxygen and chromium salts medium is poor.
Titanium alloys at low and ultra-low temperature, retain their mechanical properties. Low temperature performance, low interstitial elements of titanium, such as TA7, at -253 ℃ can maintain a certain degree of plasticity. Thus, titanium is also an important low temperature structural materials.
2015年6月18日星期四
Medical fixation titanium Frequently Asked Questions
Medical titanium plate appearance during disposal and product processing, will encounter some of the following common problems:
1. Weld Disadvantages: relatively severe shortcomings weld, the selection of craft disposal methods to compensate for mechanical polishing, grinding marks occur, the formation of the appearance of uneven effect beautiful.
2, appearance is not common: only weld pickling and passivation, but also the appearance of uneven form, affect beautiful.
3, hard to get rid of scratches: all pickling passivation, nor can happen machining process in a variety of scratches removed, and can not be removed because of scratches, weld splatter and adhering to medical titanium outer carbon fixation steel, splash and other impurities, resulting in chemical corrosion and rust or electrochemical corrosion under the conditions of the existence of corrosive media.
4,surgical implant titanium polished passivation uneven: polished craft pickling passivation disposal polishing of the area larger parts, it is difficult to reach even the role of co-disposal, not too ambitious even appearance. And work costs, materials costs are also higher.
5, pickling limited to: pickling and passivation paste is not omnipotent, plasma cutting, flame cutting and productivity and black oxide, is more difficult to get rid of.
6, scratched more severe form of the elements: the lifting, transporting and processing the layout process, scratches bump, persistent, hammering and other man-made elements of the more severe form, so look disposal difficult and also a corrosion occurred after treatment The primary reason.
7, the device elements: the profiles, sheet roll bending, bending process, the formation of scratches and creases also the main reason for the occurrence of corrosion after treatment.
8,titanium alloy plate Other elements: Medical fixation titanium raw material acquisition, storage process, because lifting, bump and scratch transport processes occur relatively severe, also One reason for the occurrence of corrosion.
1. Weld Disadvantages: relatively severe shortcomings weld, the selection of craft disposal methods to compensate for mechanical polishing, grinding marks occur, the formation of the appearance of uneven effect beautiful.
2, appearance is not common: only weld pickling and passivation, but also the appearance of uneven form, affect beautiful.
3, hard to get rid of scratches: all pickling passivation, nor can happen machining process in a variety of scratches removed, and can not be removed because of scratches, weld splatter and adhering to medical titanium outer carbon fixation steel, splash and other impurities, resulting in chemical corrosion and rust or electrochemical corrosion under the conditions of the existence of corrosive media.
4,surgical implant titanium polished passivation uneven: polished craft pickling passivation disposal polishing of the area larger parts, it is difficult to reach even the role of co-disposal, not too ambitious even appearance. And work costs, materials costs are also higher.
5, pickling limited to: pickling and passivation paste is not omnipotent, plasma cutting, flame cutting and productivity and black oxide, is more difficult to get rid of.
6, scratched more severe form of the elements: the lifting, transporting and processing the layout process, scratches bump, persistent, hammering and other man-made elements of the more severe form, so look disposal difficult and also a corrosion occurred after treatment The primary reason.
7, the device elements: the profiles, sheet roll bending, bending process, the formation of scratches and creases also the main reason for the occurrence of corrosion after treatment.
8,titanium alloy plate Other elements: Medical fixation titanium raw material acquisition, storage process, because lifting, bump and scratch transport processes occur relatively severe, also One reason for the occurrence of corrosion.
2015年6月15日星期一
Titanium medical board is widely distributed in the body
Surgical implant titanium is widely distributed in the body, normal human in an amount per 70kg body weight does not exceed 15mg, its role is still unclear. But titanium can stimulate phagocytic cells, the immune system has been shown to enhance the effect. It is widely used in medicine and sports fields. Titanium alloy plate can stimulate the phagocytes, and titanium has the ability to regulate the body's natural currents through cell ionization, the human body will produce beneficial physiological function and its chemical stability, will not Changes occur over time or deterioration, beneficial to human health. Therefore, the use of titanium products can achieve mental relaxation, muscle relaxation, improve the effect, and stimulate blood flow, increased blood flow helps your body to better substrate and remove blood from the pain and fatigue factor produced efficiently control the current disorder in the body. Bursitis, sciatica, headache these types of arthritis and premenstrual syndrome has a significant role to ease short-term pain, by regulating the body current to ease muscle pain and stiffness, improve blood circulation.
Medical titanium plate because of its high strength, metal flexibility, scalability is poor, so the high technical requirements for processing with ordinary equipment is difficult to cast molding, using ordinary tools and very difficult to weld it up, and you can not change its shape using conventional equipment, it is very easy processing of complex fracture, it is difficult to form a production scale. Thus, in the domestic jewelry market is difficult to see a real sign of titanium jewelry.
Medical titanium plate because of its high strength, metal flexibility, scalability is poor, so the high technical requirements for processing with ordinary equipment is difficult to cast molding, using ordinary tools and very difficult to weld it up, and you can not change its shape using conventional equipment, it is very easy processing of complex fracture, it is difficult to form a production scale. Thus, in the domestic jewelry market is difficult to see a real sign of titanium jewelry.
2015年5月11日星期一
OLED display - OLED display
Organic electroluminescent diodes (Organic Light-Emitting Diode, OLED) Owing to the self-luminous , no backlight, high contrast , thin, wide viewing angle , fast response , flexibility of the panel can be used for a wide temperature range, relatively simple structure and process of the other excellent features, is considered medical titanium alloy generation of flat panel display technology emerging applications . For organic electroluminescent devices , luminescent material we may be divided into two types: small molecular baoji titanium industry and a polymer OLED ( may also be referred to as PLED). Preparation of their differences mainly in the different devices : small molecule devices mainly used vacuum thermal evaporation process , the polymer devices are using spin coating or inkjet technology .
订阅: